Follow-up testing: what states say
One short-term test is a starting point. Before you decide on a fix, EPA and state health departments say to follow up, and the right follow-up depends on your first number.
Minnesota's follow-up steps
The Minnesota Department of Health says to run two tests before you decide on a mitigation system. The next test depends on the first result.
| First result | Next step |
|---|---|
| 0 to 1.9 pCi/L | Retest every 2 to 5 years. |
| 2 to 7.9 pCi/L | Do a long-term follow-up test. |
| 8 pCi/L or higher | Do another short-term test. |
Then use the average of the two short-term tests, or the single long-term result. If that result is 4 pCi/L or higher, MDH recommends mitigation. From 2 to 3.9 pCi/L, MDH says you can consider a system. Below 2 pCi/L, retest every 2 to 5 years.
Questions
Does Minnesota want a second test before a fix?
Yes. Run two tests before you decide on a mitigation system. From 2 to 7.9 pCi/L, the follow-up is a long-term test. At 8 pCi/L or higher, it is another short-term test.
Which follow-up result leads Minnesota to recommend a fix?
Use the average of the two short-term tests, or the single long-term result. At 4 pCi/L or higher, MDH recommends mitigation. From 2 to 3.9 pCi/L, MDH says you can consider a system.
Other states word it differently. Wisconsin calls levels above 4 pCi/L high. Check your own state's health department.
EPA's testing steps
EPA's Citizen's Guide to Radon has three steps.
| Step | What EPA says |
|---|---|
| 1. Short-term test | Step 1 is a short-term test. |
| 2. Follow-up at 4 pCi/L or higher | Step 2, if the result is 4 pCi/L or higher, is a follow-up. Choose a long-term test for the year-round average, or a second short-term test when you need the number sooner. |
| 3. Use the follow-up result | Step 3 depends on which follow-up you ran. A long-term result of 4 pCi/L or more means fix the home. When two short-term tests average 4 pCi/L or higher, EPA says to consider fixing. |
EPA says the higher that first short-term result is, the more reason you have to pick another short-term test for the follow-up. When the first result is more than twice the 4 pCi/L action level, take the second short-term test immediately.
Electronic radon detectors
A detector keeps measuring over time.
Corentium Home 2: $179.99
Price checked October 1, 2026
The small commission from purchases made through this link helps keep this free public directory open, at no extra cost to you.
A very high screening result
Pennsylvania DEP sends a free confirmation kit only when a screening result is over 100 pCi/L. Call 1-800-237-2366 or 717-783-3594.
Fixing the house
Hennepin County says sealing cracks is part of most radon repairs, and that sealing by itself has not been shown to lower levels in a reliable way. Most fixes use a fan and pipe system. Hire a mitigator licensed in your state. This directory does not book that work.
Next, see EPA's next step for your number or what 4 pCi/L means. Need a follow-up kit? Find a free or low-cost kit near you.